Timer;Range:0,1s÷24days;SPDT;12÷264VDC;12÷264VAC

Product Code: PCS-516-UNI
Brand
More similar products
Price when using LEMONA+ card:
and get a discount from
0.90
(-3%)
29.00

Price range

AmountPrice with tax (pcs)
1
29.90
2+
26.90
wholesale

Min. qty: 1

Unit: pcs

Total:

29.90

lemona shopPickup at the LEMONA electronics store within 2 hours (if the item is in the store and the order is placed before 3 p.m.)

Available2 pcs
Vilnius Žirmūnai Store
Available3 pcs
Vilnius Naujamiestis Store
Available4 pcs
Kaunas Store
Available2 pcs
Klaipėda Store
Available3 pcs
Šiauliai Store
Available>20 pcs
Central Warehouse (new location)

home deliveryDelivery in Lithuania 1-2 b.d.

Shipping parcelDelivery to pickup location 1-2 b.d.


Delivery terms

lemona shop

Pickup In Store

Pickup In Store For free

Orders are processed and shipped on weekdays from 8:00 a.m. to 5:00 p.m. When your order is ready for collection, we will inform you by SMS and e-mail.

Quantity in shop

Available2 pcs
Vilnius Žirmūnai Store
Available3 pcs
Vilnius Naujamiestis Store
Available4 pcs
Kaunas Store
Available2 pcs
Klaipėda Store
Available3 pcs
Šiauliai Store
Available>20 pcs
Central Warehouse (new location)
home delivery

Home delivery in Lithuania

Home delivery in Lithuania

After handing over the goods to the courier, we will inform you by e-mail. If you are ordering outside of Lithuania please use www.lemona-electronics.eu to order.

Over €70.00

(Orders up to 1000 kgs)

For free

To €70.00

(Orders up to 3 kgs)

3,49

To €70.00

(Orders up to 1000 kgs)

3,49 - 4,99 €

Shipping parcel

Delivery to a DPD Pickup location

Delivery to a DPD Pickup location

After handing over the goods to the courier, we will inform you by e-mail. Orders over €50.00 are delivered free of charge.

2,39

Product description

Timing relays PCS-516 UNI

The PCS-516 UNI time relay is used for time control in industrial and home automation systems (such as : ventilation, heating, lighting, signaling, etc.).

Functioning
The relay performs a function selected in accordance with the regime set period. The choice of a specific range of time and work the relay function is to set the appropriate combination of rotary coded switches.

A. ON delay
After the supply voltage is switched on (the green LED U is on), the contact remains in position 11-10 and the set operating time counts down. After the preset time has elapsed, the contact switches to position 11-12 (the red LED is on). To execute the operating mode of the relay again you need to switch off the power supply voltage and switch it back on.

B. OFF delay
The contact remains in position 11-10 until the relay is switched on. After the supply voltage is switched on (the green LED U is on), the contact is switched in position 11-12 and the set operating time t is measured (the red LED is on). To execute the operating mode of the relay again you need to switch off the power supply voltage and switch it back on.

C. ON delay – cyclic
On delay operating mode is carried out cyclically at equal intervals between the preset operating time and break time.

D. OFF delay – cyclic
Off delay operating mode is carried out cyclically at equal intervals between the preset operating time and break time.

E.
Generating pulse 0.5 s after the preset time t.


F.
Generating a single pulse with time t by the rising edge of the start signal. During the time measurement, the system does not react to start pulses.

G.
Generating a single pulse with time t by the trailing edge of the start signal. During the time measurement, the system does not react to start pulses.

H.
Off delay with back-up feature The rising edge of the start signal causes the relay to be switched on, while the trailing edge causes the start of time measurement. Applying the start signal during the time measurement causes the cycle to be extended by another time t with the trailing edge.

I.
Generating a single pulse 0.5 s after time t with the triggered trailing edge of the start signal.

K.
Switching off the relay for a specific time t with the rising edge of the start signal. During the time measurement, the system does not react to start signal.



Attention!
*Setting the time range knob regulator in the:
 ON - position with power supply activated results in the permanent closure of the contact in position 3-7 (UNI) and 11-12 (DUO).
 OFF - position (power supply activated) causes the contact to be permanently closed in the position 3-5 (UNI) and 11-10 (DUO).
*With the power supply on, the system does not respond to the modification of time range and operation mode.
*The newly set time range and operation mode values are active after the power supply is turned off and on or after the RESET voltage is supplied.
* With the power supply on, it is possible to regulate the preset time freely within the selected time range.
*If the function is changed into F, G, H, I, or J, one with the power supply on, and the START voltage is supplied, the system will carry out the previous function and then reset (switch into the newly selected function). A further instance of the START voltage supply will result in executing the new function.

Useful information


Specifications

SKU
251368
Weight
0.0739 kg.
Height, mm
0
Brand
Contact configuration
SPDT
Mounting
DIN
Width, mm
18
Current, A
8
Product code
PCS-516-UNI
Depth, mm
0
Rated voltage DC, V
264
Rated voltage AC, V
264
Description generated by artificial intelligenceDescription generated by artificial intelligenceDescription generated by artificial intelligenceDescription generated by artificial intelligenceDescription generated by artificial intelligenceDescription generated by artificial intelligenceDescription generated by artificial intelligenceDescription generated by artificial intelligenceDescription generated by artificial intelligenceDescription generated by artificial intelligence

Product description generated by artificial intelligence

F&F PCS-516 UNI Time Relay

The F&F PCS-516 UNI is a versatile time relay, also known as a time switch or timer, designed for precise time control in various applications. This SPDT relay is suitable for industrial and home automation systems.

Key Features and Specifications

  • Brand: F&F
  • Range: 0.1 seconds to 24 days
  • Voltage: 12-264 VDC/VAC
  • Contact Type: SPDT (Single-Pole, Double-Throw)
  • Functions: Offers 10 different timing functions, including ON delay, OFF delay, cyclic ON and OFF delay, and various pulse generation options. See the datasheet for detailed function descriptions.

Applications

This time relay finds use in a wide range of applications, such as:

  • Industrial Automation: Precise control of machinery and processes.
  • Home Automation: Managing lighting, heating, ventilation, and other systems.
  • Signaling: Controlling signals and indicators.

Why Choose the F&F PCS-516 UNI?

The F&F PCS-516 UNI provides reliable and accurate time control, making it an ideal choice for various industrial and home automation projects. Its wide range of timing functions and versatile voltage compatibility ensure its suitability for a broad spectrum of applications.

Technical Details

For detailed technical specifications, including wiring diagrams and terminal descriptions, please refer to the product datasheet.


This description is generated using artificial intelligence (AI) and may differ from the actual product. Common AI errors may include:

  • Inaccurate product features: some technical specifications, colors, sizes or other parameters may be inaccurate or omitted.
  • Incorrect compatibility information: AI may provide incorrect information about the compatibility of products with other devices or systems.
  • Overly Optimistic Functions: in some cases functions may be provided whose product iš doesnt really have.
  • Name or Model Discrepancies: AI may misrepresent the product name or model.

If you notice inconsistencies or have questions about the description, please contact us before purchasing the product, please contact us by e-mail to you: [email protected].